[StdCalibrate]¶
This section is for configuring the StdCalibrate
service. This service offers an opportunity to correct for any calibration errors in your instruments. It is very general and flexible.
Because this service is normally run after StdConvert
, the units to be used should be the same as the target unit system chosen in StdConvert
. It is also important that this service be run before the archiving service StdArchive
, so that it is the corrected data that are stored.
In a default configuration, calibrations are applied to observations from the hardware. They are not applied to derived calculations since the StdWXCalculate
service runs after StdCalibrate
.
[[Corrections]]¶
In this section you list all correction expressions. For example, say that you know your outside thermometer reads high by 0.2°F. You could add the expression:
outTemp = outTemp - 0.2
Perhaps you need a linear correction around a reference temperature of 68°F:
outTemp = outTemp + (outTemp-68) * 0.02
It is even possible to do corrections involving more than one variable. Suppose you have a temperature sensitive barometer:
barometer = barometer + (outTemp-32) * 0.0091
All correction expressions are run in the order given.
Both LOOP data and archive data will be corrected.
If you are using a Davis Vantage instrument and all you require is a simple correction offset, this can also be done in the hardware. See your manual for instructions.